CaManSys Clash Management Suite - Trial
Win32 и Win64, РусскийОбщие инструкции по использованию
Create Navisworks Manage model for Clash tests
Define Clash Tests
Run Clash tests
Write clash tests to xml file (as separate tests)
Open AutoCAD Model
Insure Clash Palette is visible
Select Clash in Clash List, resolve Clash and/or update status and comment
Repeat as necessary, open next AutoCAD Model
Review Import changes back into Navisworks Manage
Команды
Значок ленты/панели инструментов | Команда | Описание команды |
---|---|---|
|
CMSA_TLCL_CHECKUPDATE |
Check if Add-in updates are available |
|
CMSA_TLCL_LOADCONFIG |
Load Configuration File |
|
CMSA_TLCL_PURGE |
Remove Clash data from Model (AutoCAD) |
|
About |
CMSA_TLCL_ABOUT (AutoCAD) Display Add-in Information |
|
CMSA_TLCL_HELP |
Displays Help File |
|
Review |
Update/Review Clash Comments, and Statuses (Navisworks) |
|
CMSA_TLCL_XREFAUTOLOAD |
Enable / Disable Xref Autoload Switch between loading xrefs when Clash Environment opened, or on demand per clash. |
|
CMSA_TLCL_RESTOREVIEW |
Switch between Navisworks View, and saved AutoCAD View (AutoCAD Only) |
|
CMSA_TLCL_ISOLATION |
Enable/Disable Clash Isolation |
|
CMSA_TLCL_SHOW |
Show Clash Management Panel (AutoCAD) |
|
Configure |
Configure Clash Tests for current Project (Navisworks) |
|
CMSA_TLCL_REG |
Enter/Purchase Registration key. |
Установка/удаление
Run the installation file cmsClashManagement_Trial.exe.
Choose to Install AutoCAD Add-in (if AutoCAD is installed on workstation) and/or NavisWorks Manage Add-in (if Navisworks Manage is installed on workstation)
Uninstall the Addin through Control Panel\All Control Panel Items\Programs and Features->CaManSys Clash Management Suite
Дополнительная информация
Tutorial available at: http://docs.camansol.com/tutorials/cmsACTLClashTutorial/V30/index.htm
Sample file location C:\ProgramData\Autodesk\ApplicationPlugins\cmsClashManagementSuite.bundle\Samples\COS160501.zip
Известные проблемы
Not all components in the AutoCAD Model are dimmed correctly when isolating the clash components. To work around this issue, you can change the highlight colors, or turn Isolation off. This will make the clash components easier to see.
Pressing F1 for help on the ribbon buttons in Navisworks Manage does not work as expected (AutoCAD is fine). Either two tabs will be opened in the browser (Clash Management Suite on one, and Naviswork Manage Help on the other) or one tab displaying Navisworks Manage Help. The Help documentation works as expected in the panels. We are trying to figure this out.
Контактные данные
Информация о компании/авторе
Сведения о поддержке
Visit http://www.camansol.com/frames/ContactUS.html
Local: 403.457.0710
Toll free: 877.679.4965
Email: support@camansol.com
Журнал версий
Номер версии | Описание версии |
---|---|
3.0.0.1 |
Updated for AutoCAD 2020 products 3.0.0.0 New Features Performance Enhancements Disable Clash Isolation Clash Isolation can now be completely disabled. Load xrefs automatically, or on demand Xrefs can be loaded and unloaded for specific clashes Useability Enhancements Test File Names against model naming convention format Improved support for Imperial models Version 2.0.0.0 Update Licensing Framework New License Status Notification 1.5.0.0 Updated Clash File Management Clash Files are now defined in a column in the Discipline Table. 1.0.0.0 Initial Release |
3.0.0.0 |
New Features Performance Enhancements Disable Clash Isolation Clash Isolation can now be completely disabled. Load xrefs automatically, or on demand Xrefs can be loaded and unloaded for specific clashes Useability Enhancements Test File Names against model naming convention format Improved support for Imperial models Version 2.0.0.0 Update Licensing Framework New License Status Notification 1.5.0.0 Updated Clash File Management Clash Files are now defined in a column in the Discipline Table. 1.0.0.0 Initial Release |