PROCAD Unresolved References Doctor

PROCAD Unresolved References Doctor

Win64, English

PROCAD SA
Have you ever experienced opening an assembly with lost references, especially the content center ones? Did you have to replace missing parts one by one? NO MORE!

General Usage Instructions

Open an assembly with unresolved references to content center parts and press the Resolve command button located on Tools tab of Assembly Ribbon

1. Step 1: Select Content Center parts to generate and replace. Click Next button to replace and to go to the next dialog

2. Step 2: Replace other, non-content center parts manually (using the replace icon in Action column). Click OK to close the dialog

More detailed instructions are accessible in a standard way - by leaving the cursor on the command icon on a ribbon and pressing F1 key.

Note: Application licensing is based on A360 account, so the user must be logged in A360 to run the addin.

Screenshots

Commands

Ribbon/Toolbar Icon Command Command Description

Resolve

Command scans whole assembly for lost references, analyses each reference if it is a content center part and opens Unresolved References Doctor dialog window. Then, after choosing a few options, the missing parts simply appear. No effort on your side.

Installation/Uninstallation

The installer that ran when you downloaded this app/plug-in from Autodesk App Store has already installed the app/plug-in.

You can unload the plugin without uninstalling it by unchecking the "Loaded/Unloaded" check box associated with the plugin in the Autodesk® Inventor® Add-In Manager.

You may have to restart Inventor to completely unload the application.

To uninstall this plug-in, exit the Autodesk product if you are currently running it, simply rerun the installer, and select the "Uninstall" button.

OR, you can uninstall it from 'Control Panel\Programs\Programs and Features' (Windows 7/8.1/10) just as you would uninstall any other application from your system.

Additional Information

Generated parts are stored in location determined by current Inventor Project (*ipj) settings.

Content Center libraries must be installed on the user`s computer. If the libraries are not installed, the app is not able to generate and resolve Content Center parts.

Known Issues

Some parts` names are too short to carry enough information to determine what it is (to determine the content center family or size). Therefore, not every single part can be automatically resolved. However, not every time everything gets auto-replaced, automatic generation applies to most of the content center parts.

Contact

Company Name: PROCAD SA
Support Contact: apps@procad.pl

Author/Company Information

PROCAD SA

Support Information

Version History

Version Number Version Description

1.1.0

Autodesk® Inventor® 2020 update.

1.0.0

Initial version
Go top