MEP Opening
Win64, EnglishGeneral Usage Instructions
MEP Opening Plugin Usage Instructions
1. Element Origin:
- In "Structure" and "MEP Discipline," choose the origin of structural and MEP elements.
- Choose between the current model or the linked model for each discipline.
- The linked model option is only available if there are links in the current model.
- If opting for "Linked Model," select the desired model from the list.
2. Optional Parameters:
- In "Name of the MEP discipline", enter a text for identifying openings (optional).
- The entered text will be used in a specific parameter for identification in the opening family created by the plugin.
- In "Standard opening gap (cm)," set the minimum clearance for openings concerning MEP elements.
- Examples:
- A gap of 0 (zero): Openings adjusted to MEP elements without additional clearances.
- A gap of 5 (five): Minimum 5 cm distance between MEP elements and the opening instance in all directions.
- Use the diameter button to configure nominal diameters, set the default gap, and view equivalences.
3. Diameter Configuration:
- Clicking the diameter button opens a window allowing you to:
- Set the default gap for openings.
- Choose the nominal diameters considered by the plugin.
- Visualize the equivalence between MEP element diameters and the inserted opening diameter, considering the chosen gap.
4. Verification Parameters:
- Activate/deactivate minimum distance checks and configure:
- "Distance to reference beam (cm)"
- "Distance to reference slab (cm)".
5. Execution Scope:
- Select how you want to run the plugin:
- "Element selection": Openings for selected MEP elements.
- "Region bounded by elements": Openings in elements within the region bounded by the selected elements (structural and MEP).
- "Between levels": Openings in elements within the region bounded by two selected levels.
- "By section box": Openings in the crop region (floor plans) or section box (3D views), including invisible elements.
6. Execution:
- Click "Execute" after configuring the options and make selections according to the chosen scope.
7. Validations:
- If you choose to perform checks in the ‘Validation Parameters' section and the plugin detects openings that violate specified distances, a new window will open. In this window:
- Easily identify problematic openings by clicking on instances listed in each menu.
- Delete unwanted opening instances by clicking on the trash bin icon.
Commands
Installation/Uninstallation
The installer that ran when you downloaded this app/plug-in from the Autodesk App Store will start installing the app/plug-in. OR, simply double-click the downloaded installer to install the app/plugin.
You may need to restart the Autodesk product to activate the app/plug-in.
To uninstall this plug-in, exit the Autodesk product if you are currently running it, simply rerun the installer, and select the "Uninstall" button. OR, click Control Panel > Programs > Programs and Features (Windows 10/11) and uninstall as you would any other application from your system.
Additional Information
Known Issues
Contact
Author/Company Information
Support Information
For technical support, visit our website at www.itercode.com.br or contact us via email at contato@itercode.com.br.
Version History
Version Number | Version Description |
---|---|
1.1.2 |
Openings are now hosted on the closest level; Fix section box error when selecting invalid opening to inspect; Avoid creating duplicated opening when there's duplicated MEP or structural elements. |
1.1.1 |
Included an updated version of the openeing families, and now they show their revision number; Fix for handling short MEP elements and intersections; Error logs upload option; General bugfixes. |
1.0.0 |
Initial release. |